Skip to content

timelery/Kohler-DTV-Plus

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

8 Commits
 
 
 
 

Repository files navigation

Kohler-DTV-

Results of analyzing the Kohler DTV+ system controller and associated web page.

The Kohler DTV+ system controller (K-99695-NA and K-99693-P-NA) has an associated web page that is used to confogure the system components.

I spent some time looking into the web page and controller code and found a few useful pieces of information that would provie very useful if someone was inclined to interface withi this controller from another automation system.

By taking advantage of the discovered CGI scripts, someone could easily create a custom interface to manipulate the DTV+ components (Turn shower on, off, Turn on massage, Manipulate Audio or Lighting, etc).

None of this is documented by Kohler and as such such you will assume all responsibility for issues that may present themselves from interfacing with the controller in this way.

Here is a list of all CGI scripts I found that were coded into the controller. These can be executed by appending them to the end of the system controller url. For example: http://192.168.1.222/check_updates.cgi

Important: Through some initial testing I have found that some of these work and others do not. When some are executed the controller web page appears to freeze and a reboot is required. Proceed with caution. I will do some more digging and see if I can find details on whether or not any of the below cgi scripts require inputs and what those may be. Happy hacking!

check_updates.cgi landing_url.cgi mac.cgi serial.cgi clear_dt.cgi files_available.cgi reset_fault.cgi saveDT.cgi values.cgi languages.cgi rpc.cgi datatable.cgi edit_dt.cgi set_device.cgi swapvalves.cgi unpack_bin.cgi quick_shower.cgi start_user.cgi stop_user.cgi light_on.cgi light_off.cgi music_on.cgi music_off.cgi steam_on.cgi steam_off.cgi rain_on.cgi rain_off.cgi id_interface.cgi saveUI.cgi reset_factory.cgi forget_devices.cgi reset_default.cgi save_default.cgi reset_users.cgi reset_user.cgi fileupload.cgi BTKey.cgi BTPin.cgi save_variable.cgi change_user.cgi files.cgi system_info.cgi ftp_status.cgi hiding.cgi update_change.cgi bt_disconnect.cgi sim_dev_values.cgi massage_toggle.cgi powerclean_check.cgi stop_shower.cgi

Regarding the controller itself.

I have found that it is not possible to SSH into the contorller through the DHCP provided IP address. However, through analysis of the system operating system I see that they have an implementation of SSHD active on the chip. I assume that it is not enabled. There is also no active USB port. However, the board itself has pins for one. I believe Kohler has removed the USB port in the latest models.

Without a USB port and no SSH access it will be very difficult to devise another way of interfcing with the controller other than through the discovered cgi scripts.

** UPDATE **

I have found a few references to what looks to be a REST api in some of the files Iwas able to peep into.

In particular, I see a reference to "/api/v1/device/status/"

I will be spending some time looking into this to see what I can find. Stay tuned.