73 changes: 73 additions & 0 deletions templates/definition/meter/alpha-ess-smile.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -3,6 +3,13 @@ products:
- brand: Alpha ESS
description:
generic: Storion SMILE
capabilities: ["battery-control"]
requirements:
description:
de: |
softcat marked this conversation as resolved.
Show resolved Hide resolved
Um die aktive Ladesteuerung zu nutzen muss einmalig über das Webinterface oder App Zeiten für das Netzladen definiert werden. (Einstellungen->Funktionseinstellungen->Netzladen/Entladen) Hier sollte ein durchgehender Zeitraum (z.B: Ladezeit 1 00:00-23:00, Ladezeit 2 23:00-00:00) eingetragen werden. Den Schalter "Netzladen" aber deaktivieren. Die eigentliche Steuerung erfolgt über evcc. Der Entladestopp wird über eine geplante Netzladung mit einem Ziel-SoC von 10% realisiert. Alternativ können die Zeiten auch über Modbus konfiguriert werden. Dafür die Register `2134,2142,2135,2136,2144,2137,2175` auf die Werte `0,0,23,0,23,0,0,0` setzen.
en: |
To use active battery control, times for grid charging must be defined once via the web interface or app. (Settings->Function settings->Grid charging/discharging) A continuous time period should be entered here (e.g.: Charging time 1 00:00-23:00, Charging time 2 23:00-00:00). However, deactivate the "Grid charging" switch. The actual control takes place via evcc. Discharge stop is realized via a scheduled grid charge with a target SoC of 10%. Alternatively, it can also be configured via Modbus. To do this, set the registers `2134,2142,2135,2136,2144,2137,2175` to the values `0,0,23,0,23,0,0,0,0`.
params:
- name: usage
choice: ["grid", "pv", "battery"]
Expand All @@ -13,6 +20,14 @@ params:
id: 85
- name: capacity
advanced: true
- name: minsoc
default: 10
type: number
advanced: true
- name: maxsoc
default: 100
type: number
advanced: true
render: |
type: custom
{{- if eq .usage "grid" }}
Expand Down Expand Up @@ -134,4 +149,62 @@ render: |
decode: uint16
scale: 0.1
capacity: {{ .capacity }} # kWh
batterymode:
source: switch
switch:
- case: 1 # normal
set:
source: const
value: 0
set:
source: modbus
{{- include "modbus" . | indent 8 }}
register:
address: 2127 # 0x84F Time period control flag
type: writemultiple
decode: uint16
- case: 2 # hold -> Enable grid charging with 10% (default) target soc -> will not start charging but will prevent uncharging of battery
set:
source: sequence
set:
- source: const
value: 1
set:
source: modbus
{{- include "modbus" . | indent 10 }}
register:
address: 2127 # 0x84F Time period control flag
type: writemultiple
decode: uint16
- source: const
value: {{ .minsoc }}
set:
source: modbus
{{- include "modbus" . | indent 10 }}
register:
address: 2133 # 0x855 Charge Cut Soc
type: writemultiple
decode: uint16
- case: 3 # charge -> Enable grid charging with 100% target soc (will be stopped by evcc)
set:
source: sequence
set:
- source: const
value: 1
set:
source: modbus
{{- include "modbus" . | indent 10 }}
register:
address: 2127 # 0x84F Time period control flag
type: writemultiple
decode: uint16
- source: const
softcat marked this conversation as resolved.
Show resolved Hide resolved
value: {{ .maxsoc }}
set:
source: modbus
{{- include "modbus" . | indent 10 }}
register:
address: 2133 # 0x855 Charge Cut Soc
type: writemultiple
decode: uint16
{{- end }}