Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

start-logging hangs #120

Open
jakehosen opened this issue Jul 12, 2023 · 1 comment
Open

start-logging hangs #120

jakehosen opened this issue Jul 12, 2023 · 1 comment

Comments

@jakehosen
Copy link
Contributor

If you setup your sensors in the appropriate slots using set-slot-config then setup the overall deployment using set-config, start-logging will work correctly. If you power cycle the device and type start-logging again before re-entering the previous set-slot-config and set-config commands, the device will freeze and restart.

@jakehosen
Copy link
Contributor Author

jakehosen commented Jul 12, 2023

it appears that hardcoding the warmup time has fixed this problem. this should be fixed more properly at some point.