Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Value '' not in allowed values #1

Open
K4KDR opened this issue Aug 7, 2020 · 3 comments
Open

Value '' not in allowed values #1

K4KDR opened this issue Aug 7, 2020 · 3 comments

Comments

@K4KDR
Copy link

K4KDR commented Aug 7, 2020

Unable to run either tianwen1_hsd.grc or tianwen1_hsd_shortframes.grc on Ubuntu 18.04, GNU Radio 3.8, Python 3.6.9; both show the following errors in the 'Symbol Sync' block:

Param - Filterbank Arms(nfilters):
	Value '' not in allowed values

Param - PFB MF Taps(pfb_mf_taps):
	Value '' not in allowed values

... have tried my best to locate this issue but without success. Any help appreciated!

@daniestevez
Copy link
Owner

Hi Scott,

I think that's a bug with the Symbol Sync block in GNU Radio 3.8.0. Could you please try GNU Radio 3.8.1?

A workaround is to modify the Symbol Sync block and use the Interpolating Resampler option set to MMSE, 8 tap FIR instead of Polyphase Filterbank, MF.

@K4KDR
Copy link
Author

K4KDR commented Aug 7, 2020

Great information - thank you!!

Would it be possible to obtain any of the I/Q files used to test these flowgraphs? Or, are they too large to share online?

@daniestevez
Copy link
Owner

Viljo ES5PC has shared some recordings of the low rate telemetry here. For the high speed data, it might be good to ask Paul M0EYT.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment