How to connect 104NT-4-R025H42G to work. #128

Open
Sprocyon opened this issue Jun 30, 2024 · 2 comments
Open

How to connect 104NT-4-R025H42G to work. #128

Sprocyon opened this issue Jun 30, 2024 · 2 comments

Comments

@Sprocyon
Copy link

Guys, how to connect 104NT-4-R025H42G to work. What jumper positions do I need to set? For a two-wire thermister as part of a Revo hotend.

@oMTEo
Copy link

oMTEo commented Jun 30, 2024

Your thermistor needs to be plugged into TH0-Port, not the PT100/PT1000-Port, because its a NTC not a PT.

@Sprocyon
Copy link
Author

Sprocyon commented Jul 1, 2024

It works, but when it reaches 250 degrees, it fails. "Mcu shut down adc is out of range" In Config maxtemp 300. Changed it to 320, still drops on 250. What am I doing wrong?